Zero Flux Precision Current Transducers

Features:

  • Very high accuracy
  • Very low noise on the output signal
  • Linearity < 1 ppm


Applications:

  • Power & signal analysis
  • Magnet control
  • Inverters & drives development

The Ultrastab range of high performance current transducer allows the electronic measurement of DC, AC and pulsed currents with galvanic isolation between the primary (high power) circuit and the secondary circuit with <5ppm linearity and accuracy.

IT current transducers are high accuracy, large bandwidth transducers which do not use Hall generators. The magnetic flux created by the primary current is compensated by a secondary current. The zero-flux detector is a symmetry detector using two wounded cores connected to a square-wave generator. The secondary compensating current is an exact representation of the primary current.

The tables below describe the standard products, if you would like to discuss your requirement please call us on +44 (0)1793 784389 and talk to a member of our technical sales team.

IN Series

Max. Primary Continuous Direct Current Range (A)Peak Primary Current, measuring range (A)Measuring Resistance Range (Ohms)Conversion RatioMaximum withstand primary peak current (kA)Accuracy (%)Bandwidth (1dB) (kHz)Datasheet
IN 100-S+/-100+/-1500-20500:01:00200.00181000Download
IN 200-S+/-200+/-3000-151000:01:00200.0012900Download
IN 400-S+/-400+/-6000-31500:01:00200.0001750Download
IN 500-S+/-500+/-8000-2.5750:01:00-5 to 50.0018400Download
IN 1000-S+/-1000+/-15000-11500:01:00-5 to 50.0018230Download
IN 1200-S+/-1200+/-150001500:01:00-5 to 50.0018230Download
IN 2000-S+/-2000+/-30000-12000:01:00-10 to 100.0014130Download
IN 2000-SB+/-2000+/-2000---10 to 100.0075113Download
IN 2000-SB/SP1+/-2000+/-3000---10 to 100.0075113Download

IT Series

Primary Continuous Direct Current Range (A)Primary Nominal RMS Current (A)Measuring Resistance Range (Ohms)Conversion RatioOverload Capability, 100ms Pulse (A)Accuracy (%)Datasheet
IT 60-S+/- 60420 - 701 : 6000+/- 3000.027IT 60-S
IT 65-S+/- 60600 - 501 : 6000+/- 3000.03IT 65-S
IT 200-S+/- 2001410 - 301 : 1000+/- 10000.008IT 200-S
IT 205-S+/- 2002000 - 201 : 1000+/- 10000.01IT 205-S
IT 400-S+/- 4002820 - 2.51 : 2000+/- 20000.004IT 400-S
IT 405-S+/- 4004000 - 151 : 1500+/- 20000.005IT 405-S
IT 605-S+/- 6006000 - 51 : 1500+/- 30000.003IT 605-S
IT 700-S+/- 7004950 - 2.51 : 1750+/- 35000.005IT 700-S
IT 700-SB+/- 7004950 - 2.51 : 1750+/- 35000.014IT 700-SB
IT 1000-S+/- 10007070 - 31 : 1000+/- 40000.005IT 1000-S

ITN Series

Primary Continuous Direct Current Range (A)Primary Nominal RMS Current (A)Measuring Resistance Range (Ohms)Conversion RatioOverload Capability, 100ms Pulse (A)Accuracy (%)Datasheet
ITN 12-P+/- 12.58.80 - 311 : 250+/- 62.50.05ITN 12-P
ITN 600-S+/- 6004240 - 51 : 1500+/- 30000.002ITN 600-S
ITN 900-S+/- 9006362.5 - 51 : 1500+/- 45000.001ITN 900-S
ITN 1000-S+/- 10007072.5 - 51 : 1500+/- 45000.001ITN 1000-S

ITL Series

Primary Continuous Direct Current Range (A)Primary Nominal RMS Current (A)Measuring Resistance Range (Ohms)Conversion RatioOverload Capability, 100ms Pulse (A)Accuracy (%)Datasheet
ITL 900-T+/- 900400May-501 : 1500-0.009ITL 900-T
ITL 4000-S+/- 1200040000 - 11 : 2500-0.06ITL 4000-S

ITC Series

Primary Continuous Direct Current Range (A)Primary Nominal RMS Current (A)Measuring Resistance Range (Ohms)Conversion RatioOverload Capability, 100ms Pulse (A)Accuracy (%)Datasheet
ITC 2000-S/SP1+/- 300020000 - 21 : 2500-0.05ITC 2000-S/SP1
ITC 2000-S/SP2+/- 300020000 - 21 : 2500-0.05ITC 2000-S/SP2
ITC 4000+/- 600040000 - 11 : 2500-0.05ITC 4000-S

Useful Documents

pdf-icon

IT Series Catalogue

pdf-icon

IT/ITN Power Supply Datasheet

 

 

 

 

 