Stangenes wideband current transformers have been constructed in so many shapes and sizes that it is impossible to show them all at once.
The following descriptions represent broad categories, which can be reconfigured almost infinitely. For measurement of pulse and AC currents over a wide range of amplitudes, pulse lengths and frequencies.
The table below describes the standard products, if you would like to discuss your requirement please call us on +44 (0)1793 784389 and talk to a member of our technical sales team.
Max. Peak Current (A) | Max. RMS Current (A) | Pulse Rise Time (ns) | Square Pulse Droop (%/usec) | Max. Square Pulse IT (As) | Output Signal (V/A) | Datasheet | |
---|---|---|---|---|---|---|---|
0.5 - 1.0W | 500 | 5 | 10 | 0.1 | 0.002 | 1 | 0.5 - 1.0W |
0.5 - 0.1W | 5000 | 50 | 20 | 0.001 | 0.2 | 0.1 | 0.5 - 0.1W |
0.5 - 0.1WA | 5000 | 50 | 20 | 0.05 | 0.25 | 0.1 | 0.5 - 0.1WA |
0.5 - 0.05W | 10000 | 100 | 25 | 0.03 | 0.5 | 0.05 | 0.5 - 0.05W |
2 - 1.0W | 500 | 7.5 | 20 | 0.08 | 0.005 | 1 | 2 - 1.0W |
2 - 0.5W | 1000 | 15 | 20 | 0.02 | 0.02 | 0.5 | 2 - 0.5W |
2 - 0.1W | 5000 | 65 | 20 | 0.0008 | 0.5 | 0.1 | 2 - 0.1W |
2 - 0.1WA | 10000 | 65 | 20 | 0.0008 | 0.5 | 0.1 | 2 - 0.1WA |
2 - 0.025W | 20000 | 120 | 100 | 0.05 | 1 | 0.025 | 2 - 0.025W |
2 - 0.01W | 50000 | 220 | 100 | 0.0005 | 2 | 0.01 | 2 - 0.01W |