• +44 (0)1793 784389

Pulse Current Transformers

Features:

  • Complete circuit isolation
  • Internal 50 ohm termination for cable matching
  • High accuracy (+/- 0.5%)


Applications:

  • Pulse power systems

Stangenes pulse current transformers have been constructed in so many shapes and sizes that it is impossible to show them all at once.

The following descriptions represent broad categories, which can be reconfigured almost infinitely. For measurement of pulse and AC currents over a wide range of amplitudes and pulse lengths.

The table below describes the standard products, if you would like to discuss your requirement please call us on +44 (0)1793 784389 and talk to a member of our technical sales team.

Max. Peak Current (A)Max. RMS Current (A)Pulse Rise Time (ns)Square Pulse Droop (%/usec)Max. Square Pulse IT (As)Output Signal (V/A)Datasheet
0.5 - 1.05007100.050.00210.5 - 1.0
1 - 1.05007200.10.00611 - 1.0
2 - 1.05007200.050.00612 - 1.0
3 - 1.05007200.20.00213 - 1.0
3.5 - 1.05007500.010.0313.5 - 1.0
3 - 0.5100010200.050.0040.53 - 0.5
3.5 - 0.1500070500.0130.650.13.5 - 0.1
3 - 0.1500030200.350.10.13 - 0.1
3 - 0.1A500030200.0150.030.13 - 0.1A
2 - 0.1500030200.0050.060.12 - 0.1
1 - 0.1500030200.010.060.11 - 0.1
0.5 - 0.1500030100.050.020.10.5 - 0.1
0.5 - 0.051000070200.060.80.050.5 - 0.05
3.5 - 0.025200002001000.003100.0253.5 - 0.025
3 - 0.0150000100200.0210.013 - 0.01
0.5 - 0.0150000300200.00050.20.010.5 - 0.01
3.5 - 0.01500004002000.02220.013.5 - 0.01
3.5 - 0.005A2000007502500.0005400.0053.5 - 0.005A
3 - 0.00220000011001000.00550.0023 - 0.002
3.5 - 0.00150000015003000.0002800.0013.5 - 0.001

You may also like…

Capacitors

custom DC link capacitor and busbarCustom Capacitor Solutions

power ring homepage buttonPower Ring

APCS standard test kitStandard Test Kits

Ceramic Capacitors

Recent News

More Information?

Telephone +44 (0)1793 784389 or email: sales@ppm.co.uk