Browse the table below or call us on +44 (0)1793 784389 and talk to one of our technical sales team.
High Power C Series
Part Number | Max. Power (W) | Max. Voltage (V) | Current (mA) | Current Scale Factor (mA/V) | Voltage Overshoot (V) | Storage Capacitance (uF) |
---|---|---|---|---|---|---|
1/8C24-X60 | 60 | 125 | 480 | 400 | < 1 % | 0.9 |
1/8C24-X125 | 125 | 125 | 1000 | 833 | < 1 % | 0.9 |
1/8C24-X250 | 250 | 125 | 2000 | 1667 | < 1 % | 1.8 |
1/4C24-X60 | 60 | 250 | 240 | 200 | < 1 % | 0.9 |
1/4C24-X125 | 125 | 250 | 500 | 417 | < 1 % | 0.9 |
1/4C24-X250 | 250 | 250 | 1000 | 833 | < 1 % | 1.8 |
1/2C24-X60 | 60 | 500 | 120 | 109 | < 1 % | 0.43 |
1/2C24-X125 | 125 | 500 | 250 | 208 | < 1 % | 0.43 |
1/2C24-X250 | 250 | 500 | 500 | 417 | < 1 % | 0.85 |
1C24-X60 | 60 | 1000 | 60 | 50 | < 1 % | 0.019 |
1C24-X125 | 125 | 1000 | 125 | 114 | < 1 % | 0.019 |
1C24-X250 | 250 | 1000 | 250 | 227 | < 1 % | 0.038 |
2C24-X60 | 60 | 2000 | 30 | 26 | < 1 % | 0.019 |
2C24-X125 | 125 | 2000 | 62 | 52 | < 1 % | 0.019 |
2C24-X250 | 250 | 2000 | 125 | 104 | < 1 % | 0.038 |
4C24-X60 | 60 | 4000 | 15 | 11.5 | < 1 % | 0.013 |
4C24-X125 | 125 | 4000 | 31 | 26 | < 1 % | 0.013 |
4C24-X250 | 250 | 4000 | 62 | 52 | < 1 % | 0.026 |
6C24-X60 | 60 | 6000 | 10 | 6.5 | < 1 % | 0.016 |
6C24-X125 | 125 | 6000 | 21 | 17.7 | < 1 % | 0.016 |
6C24-X250 | 250 | 6000 | 42 | 35 | < 1 % | 0.026 |
8C24-X60 | 60 | 8000 | 7.5 | 4.7 | < 1 % | 0.0044 |
8C24-X125 | 125 | 8000 | 15.5 | 14.2 | < 1 % | 0.0022 |
8C24-X250 | 250 | 8000 | 31.2 | 6.25 | < 1 % | 0.0015 |
10C24-X60 | 60 | 10000 | 6 | 4.1 | < 1 % | 0.0029 |
10C24-X125 | 125 | 10000 | 12.5 | 10.9 | < 1 % | 0.0014 |
10C24-X250 | 250 | 10000 | 25 | 5 | < 1 % | 0.0015 |
12C24-X60 | 60 | 12000 | 5 | 4 | < 1 % | 0.0029 |
12C24-X125 | 125 | 12000 | 10.5 | 7.4 | < 1 % | 0.0014 |
12C24-X250 | 250 | 12000 | 20.8 | 4.17 | < 1 % | 0.00075 |
15C24-X60 | 60 | 15000 | 4 | 4 | < 1 % | 0.0022 |
15C24-X125 | 125 | 15000 | 8.3 | 7.5 | < 1 % | 0.0011 |
15C24-X250 | 250 | 15000 | 16.7 | 3.33 | < 1 % | 0.00075 |
20C24-X60 | 60 | 20000 | 3 | 0.65 | < 1 % | 0.0013 |
20C24-X125 | 125 | 20000 | 6.25 | 0.653 | < 1 % | 0.00088 |
20C24-X250 | 250 | 20000 | 12.5 | 2.5 | < 1 % | 0.00075 |
25C24-X60 | 60 | 25000 | 2.4 | 0.65 | < 1 % | 0.0011 |
25C24-X125 | 125 | 25000 | 5 | 0.65 | < 1 % | 0.00073 |
25C24-X250 | 250 | 25000 | 10 | 2 | < 1 % | 0.0005 |
30C24-X60 | 60 | 30000 | 2 | 0.65 | < 1 % | 0.00083 |
30C24-X125 | 125 | 30000 | 4.17 | 0.642 | < 1 % | 0.00055 |
30C24-X250 | 250 | 30000 | 8.33 | 1.67 | < 1 % | 0.0005 |
40C24-X60 | 60 | 40000 | 1.5 | 0.3 | < 1 % | 0.00075 |
40C24-X125 | 125 | 40000 | 3.13 | 0.63 | < 1 % | 0.00075 |
40C24-X250 | 250 | 40000 | 6.25 | 1.25 | < 1 % | 0.000375 |
50C24-X60 | 60 | 50000 | 1.2 | 0.24 | < 1 % | 0.0006 |
50C24-X125 | 125 | 50000 | 2.5 | 0.5 | < 1 % | 0.0006 |
50C24-X250 | 250 | 50000 | 5 | 1 | < 1 % | 0.0003 |
60C24-C60 | 60 | 60000 | 1 | 0.2 | < 1 % | 0.0005 |
60C24-C125 | 125 | 60000 | 2.08 | 0.42 | < 1 % | 0.0005 |
60C24-C250 | 250 | 60000 | 4.17 | 0.83 | < 1 % | 0.00025 |
Arc Detect and Arc Quench functions (8kV to 50kV only)
“Arc Detect” and “Arc Quench” are common requirements in applications such as pulsed power, electron beam, X-Ray, ion beam, and electrostatics.
Arc Detect” function ( “AD” option ):
This function generates a pulse (1 mS +5VDC) on an interface pin each time a HV arc occurs. Typical uses of this function is to assist in designing systems that count the HV arc events, stop processes, identify a fault, modify operating settings, activate another function, or safe the system.
Arc Quench function ( “AQ” option ):
This function puts a pulse (1 mS +5VDC) on an interface pin each time a HV arc occurs, reduces the HV output by >20% (Fold back) and slowly (> 2 Seconds) restores the HV back to 100%. This action can protect HV systems & devices from permanent damage as well as process materials from damage or reduced quality.
Prerequisites:
- The 8C to 50C units must also be equipped with the “-i5” or “-i10” option.
- Active LOW. Open drain MOSFET transistors
- Customer must externally limit current to less than 50mA.
- Maximum OFF state voltage 32Vdc.
- Standard 8C to 50C units with the standard 14 pin header for the “-i5” & “-i10” interface options per latest UV datasheet. Arc detect signal is available on pin 10.