- Constant current, constant voltage or constant power modes
- Internal resistance simulation
- 10 kW in a 2U high package and 15 kW in 3U
- Output voltages and currents of up to 0‑10 V/1,500 A to 0-600 V/25.5 A
Improvements over standard Genesys range
- Two user-programmable output control pins can activate external devices, such as load disconnect relays.
- Arbitrary waveform profiles (e.g. car battery simulation at vehicle start) of up to 100 steps.
- Advanced parallel master/slave system allows a multi PSU system to achieve dynamic response, ripple and noise performance comparable to a single power supply.
- Up to four units can be connected in parallel using a data link cable. The master and slave units automatically detect the parallel data connection and set their parameters accordingly.
- Faster up and down programming response times speed up operation with user adjustable voltage and current slew rate control.
Model | Output Voltage DC | Output Current | Output Power | Height (mm) |
---|---|---|---|---|
GSP10-1000 | 10V | 1000A | 10000W | 2U |
GSP10-1500 | 10V | 1500A | 15000W | 3U |
GSP20-500 | 20V | 500A | 10000W | 2U |
GSP20-750 | 20V | 750A | 15000W | 3U |
GSP30-340 | 30V | 340A | 10200W | 2U |
GSP30-510 | 80V | 510A | 15300W | 3U |
GSP40-250 | 40V | 250A | 10000W | 2U |
GSP40-375 | 40V | 375A | 15000W | 3U |
GSP50-200 | 50V | 200A | 10000W | 2U |
GSP50-300 | 50V | 300A | 15000W | 3U |
GSP60-170 | 60V | 170A | 10200W | 2U |
GSP60-255 | 60V | 255A | 15000W | 3U |
GSP80-130 | 80V | 130A | 10400W | 2U |
GSP80-195 | 80V | 195A | 15600W | 3U |
GSP100-100 | 100V | 100A | 10000W | 2U |
GSP100-150 | 100V | 150A | 15000W | 3U |
GSP150-68 | 150V | 68A | 10200W | 2U |
GSP150-102 | 150V | 102A | 15300W | 3U |
GSP200-50 | 200V | 50A | 10000W | 2U |
GSP200-75 | 200V | 75A | 15000W | 3U |
GSP300-34 | 300V | 34A | 10200W | 2U |
GSP300-51 | 300V | 51A | 15300W | 3U |
GSP400-26 | 400V | 26A | 10400W | 2U |
GSP400-39 | 400V | 39A | 15600W | 3U |
GSP500-20 | 500V | 20A | 10000W | 2U |
GSP500-30 | 500V | 30A | 15000W | 3U |
GSP600-17 | 600V | 17A | 10200W | 2U |
GSP600-25.5 | 600V | 25.5A | 15300W | 3U |
GSP Low Profile
Part Number | Output Voltage DC | Output Current | Output Power | Height |
---|---|---|---|---|
GSPL20-750 | 20V | 750A | 15kW | 2U Rack |
GSPL20-1125 | 20V | 1125A | 22.5kW | 3U Rack |
GSPL30-500 | 30V | 500A | 15kW | 2U Rack |
GSPL30-750 | 30V | 750A | 22.5kW | 3U Rack |
GSPL40-376 | 40V | 376A | 15.04kW | 2U Rack |
GSPL40-564 | 40V | 564A | 22.56kW | 3U Rack |
GSPL60-250 | 60V | 250A | 15kW | 2U Rack |
GSPL60-375 | 60V | 375A | 22.5kW | 3U Rack |
GSPL80-188 | 80V | 188A | 15.04kW | 2U Rack |
GSPL80-282 | 80V | 282A | 22.56kW | 3U Rack |
GSPL100-150 | 100V | 150A | 15kW | 2U Rack |
GSPL100-225 | 100V | 225A | 22.5kW | 3U Rack |
GSPL150-100 | 150V | 100A | 15kW | 2U Rack |
GSPL150-150 | 150V | 150A | 22.5kW | 3U Rack |
GSPL200-75 | 200V | 75A | 15kW | 2U Rack |
GSPL200-112.5 | 200V | 112.5A | 22.5kW | 3U Rack |
GSPL300-50 | 300V | 50A | 15kW | 2U Rack |
GSPL300-75 | 300V | 75A | 22.5kW | 3U Rack |
GSPL600-25 | 600V | 25A | 15kW | 2U Rack |
GSPL1000-15 | 1000V | 15A | 15kW | 2U Rack |
GSPL1000-22.5 | 1000V | 22.5A | 22.5kW | 3U Rack |
GSPL1500-10 | 1500V | 10A | 15kW | 2U Rack |
GSPL1500-15 | 1500V | 15A | 22.5kW | 3U Rack |
Compatible with existing models
The new Plus series is compatible with standard Genesys™ and Z+ models, using the same communication protocols and signals. All functions can be programmed via the front panel or remotely using the LAN (LXI 1.5), USB 2.0 or RS232/485 communications interfaces. An isolated analogue control and monitoring interface (0-5 or 0-10 V) is also provided. GPIB (IEEE488) is available as an option.
Interface options
The Anybus CompactCom platform enables various interface options as they are introduced e.g. Devicenet, Ethercat, Modbus and Profibus. A full package of software drivers, waveform creator and virtual front panel GUI is provided.
Safety features
- Safe Start – the power supply will return to its last operational settings after a power interruption but with the output disabled.
- Auto Re-Start – the power supply returns to the last used operation settings after a power interruption.
- Last Setting Memory – retains settings such as the output voltage/current, output on/off, OVP/UVL level, Fold-Back and Start-Up mode at each AC input turn-off sequence.
- Built-in protective functions – include over voltage protection (OVP), under voltage limit (UVL), fold-back protection (FOLD) and over-temperature (OTP) protection.
Certifications
Safety certifications include IEC/EN/UL 60950-1 with CE marking for the EMC, LV (low voltage) and RoHS Directives. The series conforms to the industrial environment IEC/EN61326-1 standard for conducted EMI, radiated EMI and EMC immunity.
Application Notes
Description | |
---|---|
What is isolated analogue control and how does it benefit us? | Download |
What is a power supply slew rate and can it be programmed? | Download |
How to use the GENESYS+ programmable signals | Download |
How to simulate a battery’s internal resistance using the GENESYS+ | Download |
How to generate arbitrary waveforms | Download |
How does the trigger function work on the GENESYS+ | Download |