- Constant current, constant voltage or constant power modes
- Internal resistance simulation
- 1U high, 19” (483 mm) half width rack mount
- 10 voltage models available, from 0-10 V/150 A to 0-600 V/0-2.6 A
Improvements over standard Genesys range
- Two user-programmable output control pins can activate external devices, such as load disconnect relays.
- Arbitrary waveform profiles (e.g. car battery simulation at vehicle start) of up to 100 steps.
- Advanced parallel master/slave system allows a multi PSU system to achieve dynamic response, ripple and noise performance comparable to a single power supply.
- Up to four units can be connected in parallel using a data link cable. The master and slave units automatically detect the parallel data connection and set their parameters accordingly.
- Faster up and down programming response times speed up operation with user adjustable voltage and current slew rate control.
Model | Output voltage (V) | Output current (A) | Output Power (W) |
---|---|---|---|
GH10-100 | 10 | 100 | 1000 |
GH10-150 | 10 | 150 | 1500 |
GH20-50 | 20 | 50 | 1000 |
GH20-75 | 20 | 75 | 1500 |
GH30-34 | 30 | 34 | 1020 |
GH30-50 | 30 | 50 | 1500 |
GH40-25 | 40 | 25 | 1000 |
GH40-38 | 40 | 38 | 1520 |
GH60-17 | 60 | 17 | 1020 |
GH60-25 | 60 | 25 | 1500 |
GH80-12.5 | 80 | 12.5 | 1000 |
GH80-19 | 80 | 19 | 1520 |
GH100-10 | 100 | 10 | 1000 |
GH100-15 | 100 | 15 | 1500 |
GH150-7 | 150 | 7 | 1050 |
GH150-10 | 150 | 10 | 1500 |
GH300-3.5 | 300 | 3.5 | 1050 |
GH300-5 | 300 | 5 | 1500 |
GH600-1.7 | 600 | 1.7 | 1020 |
GH600-2.6 | 600 | 2.6 | 1560 |
Compatible with existing models
The Genesys+ series is compatible with standard Genesys and Z+ models, using the same communication protocols and signals. All functions can be programmed via the front panel or remotely using the LAN (LXI 1.5), USB 2.0 or RS232/485 communications interfaces. An isolated analogue control and monitoring interface (0-5 or 0-10 V) is also provided. GPIB (IEEE488) is available as an option.
Interface options
The Anybus CompactCom platform enables various interface options as they are introduced e.g. Devicenet, Ethercat, Modbus and Profibus. A full package of software drivers, waveform creator and virtual front panel GUI is provided.
Safety features
- Safe Start – the power supply will return to its last operational settings after a power interruption but with the output disabled.
- Auto Re-Start – the power supply returns to the last used operation settings after a power interruption.
- Last Setting Memory – retains settings such as the output voltage/current, output on/off, OVP/UVL level, Fold-Back and Start-Up mode at each AC input turn-off sequence.
- Built-in protective functions – include over voltage protection (OVP), under voltage limit (UVL), fold-back protection (FOLD) and over-temperature (OTP) protection.
Certifications
Safety certifications include IEC/EN/UL 60950-1 with CE marking for the EMC, LV (low voltage) and RoHS Directives. The series conforms to the industrial environment IEC/EN61326-1 standard for conducted EMI, radiated EMI and EMC immunity.
Application Notes
Description | |
---|---|
What is isolated analogue control and how does it benefit us? | Download |
What is a power supply slew rate and can it be programmed? | Download |
How to use the GENESYS+ programmable signals | Download |
How to simulate a battery’s internal resistance using the GENESYS+ | Download |
How to generate arbitrary waveforms | Download |
How does the trigger function work on the GENESYS+ | Download |