• +44 (0)1793 784389
Schaefer 500 C Series

1600 C Series

  • Schaefer's low power C series DC/DC converters feature input/output isolation, continuous short circuit protection, wide temperature range and industrial grade build quality.

    Available in three different packages these units find application in the industrial and automotive sectors.

    Find the component you are looking for in the table below or call us on 01793 784389 and talk to one of our technical sales team.

    Input Voltage 40 – 64 VDC

    Part Number Output Voltage (V) Output Voltage Range (V) Max. Output Current (A) Avg. Output Power (W)
    C 4531 9 8 – 10 110 990
    C 4532 12 11 – 13 96 1152
    C 4533 15 14 – 16 80 1200
    C 4534 24 23 – 26 56 1344
    C 4535 28 26 – 30 50 1400
    C 4539 48 45 – 55 30 1440
    C 4536 60 58 – 68 24 1440
    C 4537 110 100 – 130 13 1430
    C 4537 J 200 190 – 200 8 1600
    C4538 220 200 – 250 6.5 1430
    C 4538 J 400 380 – 400 4 1600

    Input Voltage 50 – 80 VDC

    Part Number Output Voltage (V) Output Voltage Range (V) Max. Output Current (A) Avg. Output Power (W)
    C 4541 9 8 – 10 110 990
    C 4542 12 11 – 13 96 1152
    C 4543 15 14 – 16 80 1200
    C 4544 24 23 – 26 56 1344
    C 4545 28 26 – 30 50 1400
    C 4549 48 45 – 55 30 1440
    C 4546 60 58 – 68 24 1440
    C 4547 110 100 – 130 13 1430
    C 4547 J 200 190 – 200 8 1600
    C4548 220 200 – 250 6.5 1430
    C 4548 J 400 380 – 400 4 1600

    Input Voltage 80 – 160 VDC

    Part Number Output Voltage (V) Output Voltage Range (V) Max. Output Current (A) Avg. Output Power (W)
    C 4551 9 8 – 10 110 990
    C 4552 12 11 – 13 96 1152
    C 4553 15 14 – 16 80 1200
    C 4554 24 23 – 26 56 1344
    C 4555 28 26 – 30 50 1400
    C 4559 48 45 – 55 30 1440
    C 4556 60 58 – 68 24 1440
    C 4557 110 100 – 130 13 1430
    C 4557 J 200 190 – 200 8 1600
    C4558 220 200 – 250 6.5 1430
    C 4558 J 400 380 – 400 4 1600

    Input Voltage 160 – 320 VDC

    Part Number Output Voltage (V) Output Voltage Range (V) Max. Output Current (A) Avg. Output Power (W)
    C 4571 9 8 – 10 110 990
    C 4572 12 11 – 13 96 1152
    C 4573 15 14 – 16 80 1200
    C 4574 24 23 – 26 56 1344
    C 4575 28 26 – 30 50 1400
    C 4579 48 45 – 55 30 1440
    C 4576 60 58 – 68 24 1440
    C 4577 110 100 – 130 13 1430
    C 4577 J 200 190 – 200 8 1600
    C4578 220 200 – 250 6.5 1430
    C 4578 J 400 380 – 400 4 1600

    Input Voltage 320 – 380 VDC

    Part Number Output Voltage (V) Output Voltage Range (V) Max. Output Current (A) Avg. Output Power (W)
    C 4581 Z 9 8 – 10 110 990
    C 4582 Z 12 11 – 13 96 1152
    C 4583 Z 15 14 – 16 80 1200
    C 4584 Z 24 23 – 26 56 1344
    C 4585 Z 28 26 – 30 50 1400
    C 4589 Z 48 45 – 55 30 1440
    C 4586 Z 60 58 – 68 24 1440
    C 4587 Z 110 100 – 130 13 1430
    C 4587 ZJ 200 190 – 200 8 1600
    C 4588 Z 220 200 – 250 6.5 1430
    C 4588 ZJ 400 380 – 400 4 1600

    Input Voltage 320 – 640 VDC

    Part Number Output Voltage (V) Output Voltage Range (V) Max. Output Current (A) Avg. Output Power (W)
    C 4571 G 9 8 – 10 110 990
    C 4572 G 12 11 – 13 96 1152
    C 4573 G 15 14 – 16 80 1200
    C 4574 G 24 23 – 26 56 1344
    C 4575 G 28 26 – 30 50 1400
    C 4579 G 48 45 – 55 30 1440
    C 4576 G 60 58 – 68 24 1440
    C 4577 G 110 100 – 130 13 1430
    C 4577 GJ 200 190 – 200 8 1600
    C4578 G 220 200 – 250 6.5 1430
    C 4578 GJ 400 380 – 400 4 1600

    Input Voltage 450 – 800 VDC

    Part Number Output Voltage (V) Output Voltage Range (V) Max. Output Current (A) Avg. Output Power (W)
    C 4571 K 9 8 – 10 110 990
    C 4572 K 12 11 – 13 96 1152
    C 4573 K 15 14 – 16 80 1200
    C 4574 K 24 23 – 26 56 1344
    C 4575 K 28 26 – 30 50 1400
    C 4579 K 48 45 – 55 30 1440
    C 4576 K 60 58 – 68 24 1440
    C 4577 K 110 100 – 130 13 1430
    C 4577 KJ 200 190 – 200 8 1600
    C4578 K 220 200 – 250 6.5 1430
    C 4578 KJ 400 380 – 400 4 1600

  • Efficiency
    80 - 92% typical

    Overload Protection
    Current limited to 105 - 110 % nominal value

    Overvoltage Protection
    OVP switches off module with automatic return to operation

    Cooling Method
    Air cooled (increased airflow recommended)

    Operating Temperature
    -20 to +75 deg.C (optional -40 to 75 deg.C)
    Derate 2.5% per deg.C over 55 deg.C

    Protection Category
    IP20 acc. to EN 60529
    (other upon request)

    Conducted & Radiated EMI
    Acc. to EN 61000-6-4, class A (optional class B)

    Safety Category
    Acc. to EN 60950-1 / EN 50178

    Dimensions
    Eurorack: 6U x 21TE x 306 mm
    Wall mount: 360 x 140 x 340 mm
    Chassis mount: 295 x 125 x 340 mm

    Weight
    Eurorack: 6.5 kg
    Wall mount: 10 kg
    Chassis mount: 7.5 kg

More Information?