    OL600W Series

    Part Number Output Voltage (kV) Output Current (mA) Rack Size Voltage Ripple (Voltage Mode) Voltage Ripple (Current Mode) Line Voltage Regulation Load voltage Regulation Line Current Regulation Load Current Regulation
    OL600W-102x 1 600 1U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
    OL600W-502x 5 120 1U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
    OL600W-103x 10 60 1U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
    OL600W-203x 20 30 1U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
    OL600W-303x 30 20 1U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
    OL600W-403x 40 15 1U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
    OL600W-503x 50 12 1U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
    OL600W-603x 60 10 1U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
    OL600W-803x 80 7.5 2U < 0.1% < 0.5% < 0.05% < 0.05% < 0.5% < 0.5%
  • Input voltage & frequency
    185VAC - 255VAC or 103VAC - 127VAC (auto range selection)
    47 - 63 Hz single phase

    Voltage & Current Programming (Analog)
    Voltage: 0 - 10 V
    Current: 0 - 10 V

    Communication Interface
    25-pin sub-D-socket

    Efficiency
    > 75%

    Polarity
    Positive or negative
    (replace x in part number with P or N)

    Protection
    Over temperature
    Over voltage
    Fan failure
    Current limit
    Series output resistance
    Arc count and extinguish

    Operating Temperature
    0 - 40 deg.C

    Cooling
    Fan assisted with fan fail detection
    Minimum air flow 3m/s at input fan

    Temperature Coefficient (following 30min warm up)
    < 100ppm per Deg.C

    Certifications & Standards
    CE marked for EU LV directive 2006/95/EC
    RoHS compliant to EU directive 2011/65/EU
    Complies with SEMI F47 standard

    Weight
    Up to 60kV units: 6.5kg
    80kV unit: 8kg

    Dimensions
    Up to 60kV units: 496.9 L x 429.6 W x 41.9 (1U) H mm
    80kV unit: 496.9 L x 422.8 W x 88.1 H (2U) mm

  •  
     
     
     